Gibson GCG91226XA Uživatelský manuál Strana 24

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 28
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 23
5. Replace the rating plate (it is near the gas
supply pipe) with the one for the new type
of gas supply.
You can find this plate in the
bag supplied with the
appliance.
If the supply gas pressure is not constant or it
is different from the necessary pressure,
install an applicable pressure adjuster on the
gas supply pipe.
Adjusting the minimum gas level on the
hob burner
1. Disconnect the appliance from the
electricity.
2. Remove the knob for the hob. If there is
no access to the bypass screw dismount
the control panel before adjustment start.
3. With a thin and flat screwdriver adjust the
bypass screw A.
The model determines the position of the
bypass screw A.
Changing from natural gas to liquid
gas
1. Fully tighten the bypass screw.
2. Put the knob back.
Changing from liquid gas to natural
gas
1. Unscrew approximately one turn the
bypass screw position A.
2. Put the knob for the hob back.
3. Connect the appliance to the electricity.
WARNING!
Put the mains plug into the
mains socket only if all parts
are back into their initial
position. There is a risk of
injury.
4. Light the burner.
Refer to "Hob - Daily use" chapter.
5. Turn the knob for the hob to the minimum
position.
6. Remove the knob for the hob again.
7. Screw on slowly the bypass screw till the
flame becomes minimum and stable.
8. Put the knob for the hob back on.
Oven injector replacement
1. Remove the bottom plate of the oven
cavity to get access to the oven burner .
2. Carefully remove from the burner the
thermocouple A. Next remove the spark
plug B.
24